Universal DNA Extraction Kit
(Silicone Membrane Centrifugal Column Method)
Cat. No./Spec.: N1211/24 preps; N1212/100 preps
Kit Contents
Component | N1211 | N1212 |
Buffer ATL | 10 ml | 30 ml |
Buffer AL | 10 ml | 30 ml |
Buffer SW1 | 20 ml | 60 ml |
Buffer SW2 | 30 ml | 110 ml |
Proteinase K | 0.6 ml | 2.5 ml |
Elution Buffer | 10 ml | 20 ml |
DNA Spin Column | 24 pcs | 100 pcs |
Collection Tube | 24 pcs | 100 pcs |
Description
This product utilizes column purification technology, suitable for extracting high-purity DNA from animal tissues, processed animal-derived samples, cultured cells, exfoliated cells, blood, saliva, swabs, bloodstains, bacteria, and other samples. The purification principle involves lysing cells with cell lysis solution to release genomic DNA, which is then reversibly adsorbed by the silicone membrane column. After digestion with proteinase K and washing with wash solution to remove proteins, lipids, and polysaccharides, the genomic DNA is eluted with pure water to obtain the genomic DNA. The extraction process does not require the use of toxic phenol-chloroform extraction or time-consuming alcohol precipitation. The digestion process after extraction only takes 20 minutes. The obtained DNA can be directly used for PCR, quantitative PCR, Southern Blot, viral DNA detection, and second-generation sequencing experiments.
Storage
This product can be stored at room temperature (15~25 ̊C) for 18 months. Buffer ATL may precipitate at low temperatures, which can be dissolved by incubating at 55ºC and mixing thoroughly. The product uses PET reagent bottles, which should not be subjected to high-temperature, high-pressure sterilization or direct incubation above 55ºC.