tel.png Tel: +86 20 31600213    mail.png Sales EMail: order@gdsbio.com      

V5009 One-step Probe RT-qPCR Kit V2

Products & Applications > 1-step RT-qPCR > V5009 One-step Probe RT-qPCR Kit V2

V5009 One-step Probe RT-qPCR Kit V2

Price: $320.00~4462.00
V5009 (200 rxns) V5010 (5000 rxns)

Product Introduction

The One-step Probe RT-qPCR Kit V2 is designed for quantitative PCR detection using RNA as a template, such as viral RNA. Using gene-specific primers (GSP), reverse transcription and qPCR reactions are performed in a single tube, requiring no additional tube opening/pipetting, significantly increasing detection throughput and reducing the risk of contamination. This Kit introduced dUTP/UDG system. Heat-labile UDG can rapidly degrade the pollutants containing U at room temperature. When reverse transcription is performed at 55°C, heat-labile UDG will be inactivated rapidly without affecting the efficiency and sensitivity of RT-qPCR. Thermostable reverse transcriptase can maintain stable activity at 55°C. The hot-start antibody-modified fast DNA polymerase and optimized buffer system ensure the extremely high sensitivity and specificity of the One-Step Probe RT-qPCR Kit V2. The kit is available as a convenient Master Mix. 2X RT-qPCR Mix contains an optimized buffer system and dNTP/dUTP Mix, which is suitable for high-specificity detection systems with fluorescent labeled probes such as TaqMan®.

 

Selection Guide of One-Step Kit (probe based):

Cat. No.


V5001/V5002

V5005/V5006

V5005L/V5006L

V5007/V5008

V5007L/V5008L

V5009/V5010

V5011

Product Name


One-step Probe RT-qPCR Kit

DSPathTM 4X One-Step Multiplex Master Mix

DSPathTM 4X One-Step Multiplex Master Mix (Lyophilized)

2X One Step Prime RT-qPCR Mix

2X One Step Prime RT-qPCR Mix (Lyophilized)

One-step Probe RT-qPCR Kit V2

One-step Probe RT-qPCR Kit V3

Mixture Format


Enzyme Mix+2X Buffer Mix

4X All-in Mix

4X All-in Lyophilized Powder

2X All-in Mix

2X All-in Lyophilized Powder

Enzyme Mix+2X Buffer Mix

Enzyme Mix+5X Buffer Mix

Mode/Time


S: ~120 min

F: ~60 min S: ~120 min

F: ~60 min S: ~120 min

F: ~60 min S: ~120 min

F: ~60 min S: ~120 min

F: ~60 min S: ~80 min

F: ~45 min S: ~80 min

RT TEMP


50~55°C

48~55°C

48~55°C

48~55°C

48~55°C

50~55°C

50~55°C

PCR Enzyme


Antibody-modified hotstart Taq

Antibody-modified hotstart Taq

Antibody-modified hotstart Taq

Antibody-modified hotstart Taq

Antibody-modified hotstart Taq

Antibody-modified hotstart Taq

Antibody-modified hotstart Taq

Heat-labile UDG


+

+

+

+

+

+

+

Sensitivity


Very high

Very high

Very high

Very high

Very high

Ultra high

Ultra high

S: standard mode; F: fast mode

V5005, V5009, and V5011 are recommended

 

Application

Probe gene expression analysis

Probe Low-copy gene detection

Probe microarray validation

Probe gene knockdown validation

Features

Fast start-up, 30s hot start

Reverse transcription at 55 °C to accommodate complex RNA templates

Contains heat-labile UDG to reduce false-positive contamination

High sensitivity for detection of low-abundance genes

High stability, unchanged performance at 4°C and 37°C for one week

The reaction system can be formulated up to 30 minutes in advance without changing performance

Saves time by supporting fast program

Experimental Cases

A. Sensitivity: The LOD of Novel Coronavirus is up to 200 copies/ml

 

B. Stability: when stored at 4°C and 37°C for a week, the performance does not change significantly:

  

 

 

C. Performance comparison test with other suppliers:

compared with Chinese manufacturers: better performance than the supplier N and supplier B.

Test sample: pseudovirus of SARS-CoV-2                       




 

 

Comparison with international suppliers: no matter the use of standard mode, or fast mode, performance is not lost to international well-known brands.

Test sample: pseudovirus of SARS-CoV-2                       





  

 

No immediate reaction is required after the reaction system is formulated. The system can be stored at RT before reaction, and the performance has no obvious effect within 30 minutes.

Test sample: pseudovirus of SARS-CoV-2  

Sheet 1: perform reaction immediately after the reaction system is ready

Dilution fold

1

2

10

Supplier

Gene

CT

SD

n

CT

SD

n

CT

SD

n

GDSBIO

N

35.53

0.49

10

36.86

0.58

10

39.25

0.75

8

B

36.33

0.56

10

37.54

0.89

10

39.69

1.29

5

GDSBIO

RNaseP

35.97

0.51

10

36.41

0.89

10

38.86

0.62

9

B

35.51

0.46

10

36.69

1.17

10

38.34

0.98

9

GDSBIO

ORF1ab

35.22

0.74

10

36.37

1.09

10

37.29

0.63

4

B

35.74

0.66

10

37.23

2.38

8

38.52

0.20

2

 

Sheet 2: perform reaction 30min after the reaction system is ready and placed at RT

Dilution fold

1

2

10

Supplier

Gene

CT

SD

n

CT

SD

n

CT

SD

n

GDSBIO

N

34.88

0.56

10

35.48

0.59

10

38.18

0.44

5

B

35.65

0.81

10

38.24

2.67

7

39.47

2.64

3

GDSBIO

RNaseP

35.80

0.44

10

35.76

0.59

10

37.88

0.73

8

B

34.80

0.27

10

36.00

1.06

10

39.93

2.17

7

GDSBIO

ORF1ab

35.65

0.62

10

37.53

1.06

8

38.69

0.72

7

B

null

null

0

null

null

0

null

null

0

                     

The performance of V5009 does not change when the reaction system is prepared 30 minutes in advance. However, the testing performance of Company B product decreased significantly after it was left at room temperature for 30min after reaction system was ready.

 


Components

Component

V5009

(200 rxns)

V5010

(5000 rxns)

2X One-step U+ Mix

760 μl × 4 

38.4 ml × 2

One-step U+ Enzyme Mix V2

308 μl  

7.7 ml


Storage Condition

Store at 2~8°C


Name
Phone
Email
Corporate name
Address
Leaving Message*
 
Verification code
Submit