tel.png Tel: +86 20 31600213    mail.png Sales EMail: order@gdsbio.com      

Multiplex Probe qPCR Mix Plus U (Low ROX+) P2701a/P2702a/P2703a/P2704a

Products & Applications > Molecular Research Reagents > Multiplex Probe qPCR Mix Plus U (Low ROX+) P2701a/P2702a/P2703a/P2704a

Multiplex Probe qPCR Mix Plus U (Low ROX+) P2701a/P2702a/P2703a/P2704a

Price: $51.50~3875.00
P2701a(1 mL) P2702a(1 mL×5) P2703a(50 mL) P2704a(100 mL)

Multiplex Probe qPCR Mix Plus U (Low ROX+)

For research use only

Cat. No./Spec.

Cat. No.

P2701a

P2702a

P2703a

P2704a

25-μl rxn Nos 

80 rxns

400 rxns

4000 rxns

8000 rxns

 

Components  

Component

P2701a

P2702a

P2703a

P2704a

2× Multiplex Probe qPCR Mix Plus U (Low ROX+) 

1 ml

1 ml × 5

50 ml

100 ml

Nuclease-free Water

1 ml

1 ml × 5

-

-

 

Storage

This reagent can be stored for 2 months at 4°C. For longer storage, it should be kept at -20°C.

 

Description

Multiplex Probe qPCR Mix Plus U (Low ROX+) is a 2× concentrated premix for real-time quantitative PCR with probe method. In use, just add the DNA template, primer and probe to react. This product contains antibody technology modified Hotstart Taq DNA polymerase. Combined with GDSBio's special real-time PCR Buffer, it can not only effectively inhibit primers dimer and other non-specific amplification, but also improve the amplification efficiency, allowing multi-probe qPCR reaction. This reagent introduced dUTP/UDG anti-contamination system, which can remove PCR products containing dUTP before PCR reaction, effectively avoid the influence of cross contamination of amplification products on quantification. This product is convenient for use with TaqMan, primers to achieve a fully premixed Master Mix molecular diagnostic kit, and is perfectly compatible with common quantitative PCR instruments, such as ABI, Roche, Bio-Rad, etc. The product has been pre-mixed with low-concentration ROX reference dye, which is suitable for ABI, Roche and other fluorescent quantitative PCR instruments requiring low-concentration ROX for calibration. It can be used with TaqMan and other fluorescent probes.

The reaction system of this product can be prepared at room temperature without an ice box. The prepared PCR reaction system can be placed at room temperature for 24 hours and the amplification efficiency remains unchanged.


Application

• Probe gene expression analysis

Multiple Low-copy gene detection

• Probe microarray validation

• Probe gene knockdown validation

Features

• This kit is suitable for Multiplex fluorescence quantification by probe method

• This kit is compatible with many real-time systems require low-concentrtion ROX to calibrate

• Hot-start technology brings high specificity and reproducible amplification

dUTP/UDG system, effectively prevent PCR product contamination

Experimental Cases

Using human genome DNA as template, it has good multiplex amplification performance.

1703205598726.jpg

Components

Component

P2701a

P2702a

P2703a

P2704a

2× Multiplex Probe qPCR Mix Plus U (Low ROX+)

1 ml

1 ml × 5

50 ml

100 ml

Nuclease-free Water

1 ml

1 ml × 5

-

-

Storage Condition

Store at -20°C 


Name
Phone
Email
Corporate name
Address
Leaving Message*
 
Verification code
Submit